{"product_id":"riscaldatore-ibc-atex-serie-lb-da-1000-litri-1700-w","title":"ATEX IBC Heater LB Series 1000 Liters – 1700 W","description":"\u003ctable\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eProduct code\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e24-4651\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eHeater for IBC containers\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eATEX LB\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eContainer capacity\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e1000 litres\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e230 V\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e1700 W\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eDegree of protection\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eIP54\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e4400 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003ePower cable\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e5 m – 3G1.5 mm²\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e63 kg\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003ePackaging dimensions\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e1200 × 800 × 600 mm\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eHeating cable\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eSelf-regulating\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eOuter material\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eAntistatic and water-repellent PVC fabric, fire reaction class B2\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eControl unit\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eNot required and not compatible\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eRecommended insulating cover\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eCode 24-4652\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eATEX certifications of the series\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eCETS 23 ATEX 030 X; CETS 23 ATEX 031 U\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eIndicated ATEX zones\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e1, 2, 21 and 22\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eIndicated temperature classes\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eT6, T5, T4, T3, T2, T1\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003e65 °C under voltage \/ 85 °C without voltage\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cspan\u003eAmbient temperature\u003c\/span\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cspan\u003eFrom -20 °C to +55 °C\u003c\/span\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000-litre ATEX LB series IBC heater\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for heating IBC containers in environments with a risk of explosive atmospheres. It is particularly suitable for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efrost protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping to prevent the contents from freezing during storage and handling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eself-regulating heating cable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, adapted to the volume of the container, and an antistatic and water-repellent PVC outer cover. The structure has a degree of protection IP54 and an ATEX-certified junction box, which allows the heating cable to be replaced.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike models that require an external control unit, the LB series operates without a controller: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eit is not possible to purchase or connect a temperature control unit to this model\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. To improve temperature maintenance and limit heat loss, it is recommended to use it with the insulating cover, code 24-4652.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eDesigned for 1000-litre IBC containers.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003ePower: 1700 W, 230 V power supply.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eSelf-regulating heating cable.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eDegree of protection IP54.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eAntistatic and water-repellent PVC outer cover, class B2.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eATEX-certified junction box, designed for cable replacement.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003e5-metre power cable, 3G1.5 mm² cross-section.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eOperating temperature: 65 °C under voltage and 85 °C without voltage.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eAmbient temperature: from -20 °C to +55 °C.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eOperation without a control unit: there is no provision for connecting one.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cspan\u003eInsulating cover code 24-4652 recommended.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIndustries and applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eChemical industry:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e frost protection and temperature maintenance of products contained in IBCs.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePetroleum industry and oil treatment:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e support for liquid preservation during storage.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePharmaceutical industry:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e thermal management of containers according to process requirements.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial storage and handling:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e frost protection of liquids contained in 1000-litre IBCs.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eExplosion risk environments:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e use in the ATEX zones indicated for the series, in compliance with the conditions and configuration required by the certification.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Mayermoover","offers":[{"title":"Default Title","offer_id":55126718185818,"sku":"24-4651","price":6603.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/9990\/8228\/files\/24-4651_1.png?v=1793798035","url":"https:\/\/mayermoover.com\/en-en\/products\/riscaldatore-ibc-atex-serie-lb-da-1000-litri-1700-w","provider":"Mayermoover","version":"1.0","type":"link"}