Skip to content

Fast Shipping

Call us or write to us on WhatsApp

Collection tank for 2 x 200 LT drums - RAL 6011

Collection tank for 2 x 200 LT drums - RAL 6011

Regular price
€252,53 VAT excluded
€252,53 VAT excluded
Regular price €368,03
€252,53 VAT excluded
€252,53 VAT excluded
Sale price

Product Description

ART. TO B C D AND Capacity
SVR2F 1380 850 230 100 330 2 200 Lt drums

A=Length
B=Width
C=Useful height
D=Foot height
E=Total height
The measurements are expressed in millimeters

General information

This Mayermoover metal collection tank , designed to accommodate two 200-litre drums, is made with a carbon steel structure and RAL 6011 (reseda green) paint finish , ideal for environments where a discreet but effective colour distinction between storage locations is required.

The solution is designed to ensure maximum safety against accidental spills , contributing to environmental protection and compliance with current European regulations on workplace safety.

Reinforced structure and selected materials

Each tank is constructed from 3mm (30/10) thick S235JR quality carbon steel with electronically tested welds to ensure absolute watertightness. The included, pressed hot-dip galvanized grating is designed to withstand high loads and potentially corrosive environments.

Production is carried out according to UNI parameters , using raw materials certified by suppliers compliant with the UNI EN ISO 9001 standard. Material traceability is guaranteed and can be documented upon request.

Technical features

  • Capacity: 2 x 200 litre drums

  • Frame: S235JR or higher carbon steel

  • Thickness: 3 mm

  • Painting: epoxy powder RAL 6011 (reseda green)

  • Grating included: hot-dip galvanized and pressed

  • Electronically controlled welding

  • Handling by forklift forks

  • Product compliant with UNI regulations

  • Certifications available upon request

Other finishes available

  • Single or two-component liquid painting

  • Hot or cold galvanizing

  • Custom RAL colors on request (with minimum quantities)

Recommended use

  • Workshops and maintenance departments

  • Technical areas and factories with differentiated management of drums

  • Plants subject to strict environmental protocols

  • Industrial environments that require visual order and chromatic distinction

Storage and Retention Guide

What does the law say?
According to Legislative Decree 19/05/1999 n. 152 , amended by Legislative Decree 2000 n. 258 , containment basins must have a minimum capacity at least equal to the largest of the stored containers and in any case not less than 1/3 of the total volume of the hazardous substances present. In areas subject to groundwater protection, the legislation instead requires that the entire stored volume be contained within the collection tank ( 100% of the volume ).

⚠️ Attention:
This regulation does not apply to the storage of used oil , for which the law expressly requires a containment tank equal to 100% of the stored volume , regardless of other considerations.

To better clarify the practical application of these rules, we report below two examples with explanatory data:

Liquid containment diagram
Parameter Example 1 Example 2
Total substances stored 1500 liters 3600 liters
1/3 of the total 500 liters 1200 liters
Larger container 700 liters 1000 liters
Minimum capacity required 700 liters
(being 700 > 500)
1200 liters
(being 1000 < 1200)