General information

This one Mayermoover metal collection tank, designed to accommodate two 200 liter drums, is made with a carbon steel structure and RAL 6011 painting (reseda green), ideal for environments where a discrete chromatic distinction but effective between storage locations.

The solution is designed for guarantee maximum safety against accidental spills, contributing to the protection of the environment and compliance with current European regulations in the field of workplace safety.

Reinforced structure and selected materials

Every containment tank for forklift is built in S235JR quality carbon steel, with thickness 3 mm (30/10) e welds tested electronically to ensure absolute watertightness. The hot-dip galvanized grating, embedded and pressed, is designed to withstand high loads and potentially corrosive environments.

Production takes place according to UNI parameters, with the use of certified raw materials from suppliers compliant with the standard UNI EN ISO 9001. The traceability of materials is guaranteed and can be documented upon request.

Technical characteristics

  • Capacity: 2 200 liter drums

  • Structure: S235JR carbon steel or higher

  • Thickness: 3mm

  • Painting: epoxy powder RAL 6011 (reseda green)

  • Grating included: hot-dip galvanized and pressed

  • Welding with electronic control

  • Handling using forklift forks

  • Product compliant with UNI regulations

  • Certifications available upon request

Other finishes available

  • Single or two-component liquid painting

  • Hot or cold galvanizing

  • Customized RAL colors on request (with minimum quantities)

Recommended use

  • Workshops and maintenance departments

  • Technical areas and factories with differentiated management of the drums

  • Plants subject to strict environmental protocols

  • Industrial environments that require visual order and chromatic distinction

Storage and Retention Guide

What does the law say?
As established by Legislative Decree 19/05/1999 n. 152, modified by Legislative Decree 2000 n. 258, containment basins must have a minimum capacity equal to at least the largest of the containers stored e in any case not less than 1/3 of the total volume of the dangerous substances present. In areas subject to aquifer protection, the legislation requires that the entire stored volume be contained within the collection tank (100% of the volume).

⚠️ Attention:
This rule does not apply to the storage of used oil, for which the law expressly requires a containment tank equal to 100% of the stored volume, regardless of other considerations.

To better clarify the practical application of these rules, below are two examples with explanatory data:

Liquid containment diagram

Parameter Example 1 Example 2
Total substances stored 1500 litres 3600 litres
1/3 of the total 500 litres 1200 litres
Larger container 700 litres 1000 litres
Minimum capacity required 700 litres
(being 700 > 500)
1200 litres
(being 1000 < 1200)