Conical collection tank for 2 200 liter drums - Galvanized
Conical collection tank for 2 200 liter drums - Galvanized
Product Description
| 4ART. | A | B | C | D | E | Scope |
|---|---|---|---|---|---|---|
| FM102CN | 1200 | 800 | 340 | 100 | 440 | 2 200 liter drums |

A=Length
B=Width
C=Usable height
D=Foot height
E=Total height
The measurements are expressed in millimetres
General information
The Mayermoover conical collection tank for 2 200 liter drums it's ours entry level model, designed to offer an accessible, yet safe and efficient, alternative for storing hazardous liquids in standard drums. Designed to meet the needs of those looking for a reliable container that complies with regulations, it represents the right choice for work environments where spill prevention is fundamental.
Liquid containment tank made of galvanized steel, corrosion resistance, durability and ease of handling thanks to the seats for mounting. The conical design facilitates the drainage of liquids and makes cleaning and maintenance easier.
Main features
-
Bathtub made in carbon steel with thickness of 3mm (30/10)
-
Galvanized for optimal protection from atmospheric agents and aggressive substances
-
Conical design for an easier flow of waste
-
Galvanized pressed grating compliant with regulations, with high flow rate
-
Continuous non-rejoined welds electronically tested to ensure watertightness
-
Front mounting for handling with forklift
-
Built according to parameters UNI, with quality materials S235JR or higher
-
Certified and traceable according to UNI EN ISO 9001
Ideal for:
-
Mechanical workshops
-
Chemical and painting plants
-
Industrial sectors where 200 liter drums are used
-
Temporary storage areas for dangerous substances
Why choose a Mayermoover bathtub
-
Each tank is subjected to strict leak testing and quality control
-
Exclusive use of certified and high quality raw materials
-
Produced in Italy with attention to safety and environmental sustainability
Storage and Retention Guide
What does the law say?
As established by Legislative Decree 19/05/1999 n. 152, modified by Legislative Decree 2000 n. 258, containment basins must have a minimum capacity equal to at least the largest of the containers stored e in any case not less than 1/3 of the total volume of the dangerous substances present. In areas subject to aquifer protection, the legislation requires that the entire stored volume be contained within the collection tank (100% of the volume).
⚠️ Attention:
This rule does not apply to the storage of used oil, for which the law expressly requires a containment tank equal to 100% of the stored volume, regardless of other considerations.
To better clarify the practical application of these rules, below are two examples with explanatory data:

| Parameter | Example 1 | Example 2 |
|---|---|---|
| Total substances stored | 1500 litres | 3600 litres |
| 1/3 of the total | 500 litres | 1200 litres |
| Larger container | 700 litres | 1000 litres |
| Minimum capacity required | 700 litres (being 700 > 500) |
1200 litres (being 1000 < 1200) |